Saiba mais sobre o produto:
General Specifications
Cable Type Central loose tube
Construction Type Armored
Subunit Type Gel-filled
Construction Materials
Fiber Type Solution TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1 | OS2)
Jacket Material PE
Total Fiber Count 6
Armor Type Corrugated steel
Fiber Type TeraSPEED®, zero water peak singlemode fiber (G.652.D, G.657.A1 | OS2)
Fiber Type, quantity 6
Fibers per Subunit, quantity 6
Jacket Color Black
Jacket UV Resistance UV stabilized
Dimensions
Buffer Tube/Subunit Diameter 4.00 mm | 0.16 in
Cable Weight 135.0 kg/km | 91.0 lb/kft
Diameter Over Jacket 11.00 mm | 0.43 in
Subunit, quantity 1
Physical Specifications
Minimum Bend Radius, loaded 16.5 cm | 6.5 in
Minimum Bend Radius, unloaded 11.0 cm | 4.3 in
Tensile Load, long term, maximum 180 lbf | 800 N
Tensile Load, short term, maximum 2700 N | 607 lbf
Vertical Rise, maximum 607.0 m | 1991.5 ft
Environmental Specifications
Environmental Space Aerial, lashed | Buried
Installation Temperature -30 °C to +70 °C (-22 °F to +158 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression 250 lb/in | 44 N/mm
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 35 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 2.17 ft lb | 2.94 N-m
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7
Water Penentration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze -2 °C | 28 °F
Cable Freeze Test Method FOTP-98 | IEC 60794-1 F15
Drip 70 °C | 158 °F
Drip Test Method FOTP-81 | IEC 60794-1 E14
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -30 °C to +60 °C (-22 °F to +140 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1
Qualification Specifications
Cable Qualification Standards ANSI/ICEA S-87-640 | EN 187105 | Telcordia GR-20
Fale com nossos especialistas em SYSTIMAX
Veja mais
CABO OPTICO SM 9/125 EXTERNO AUTO-SUSTENTAVEL 6F
- Código GP Cabling: 18006
- Part Number: CFOA-SM-ASU80-06-NR
- Unidade: Metro
CORDÃO ÓPTICO DUPLEX 50,0/125 LC/LC OM2 1,5M
- Código GP Cabling: 44138
- Part Number: N222.2LLY1
- Unidade: Peça
CORDÃO ÓPTICO DUPLEX SM- OS2 LC/LC LSZH 3,0 M AMARELO
- Código GP Cabling: 95920
- Part Number: 2105028-3
- Unidade: Peça
CORDAO DUPLEX LAZRSPEED LC/LC 10FT - 3,05M
- Código GP Cabling: 50475
- Part Number: FDXLCLC42-MXF010
- Unidade: Peça