Saiba mais sobre o produto:
General Specifications
Construction Type Non-armored
Cable Type Distribution
Construction Materials
Total Fiber Count 12
Fiber Type G.652.D and G.657.A1 , TeraSPEED®
Fiber Type Solution G.652.D and G.657.A1 , TeraSPEED®
Fiber Type, quantity 12
Jacket Color Black
Jacket UV Resistance UV stabilized
Physical Specifications
Minimum Bend Radius, loaded 10.8 cm | 4.3 in
Minimum Bend Radius, unloaded 7.2 cm | 2.8 in
Tensile Load, long term, maximum 120 lbf | 534 N
Tensile Load, short term, maximum 400 lbf | 1780 N
Vertical Rise, maximum 500.0 m | 1640.4 ft
Dimensions
Cable Weight 33.0 lb/kft | 49.0 kg/km
Diameter Over Jacket 7.20 mm | 0.28 in
Physical Specifications
Minimum Bend Radius, loaded 10.8 cm | 4.3 in
Minimum Bend Radius, unloaded 7.2 cm | 2.8 in
Tensile Load, long term, maximum 120 lbf | 534 N
Tensile Load, short term, maximum 400 lbf | 1780 N
Vertical Rise, maximum 500.0 m | 1640.4 ft
Flame Test Specifications
Flame Test Listing NEC OFNR-LS (ETL) and c(ETL)
Flame Test Method IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL 1666 | UL 1685
Environmental Specifications
Environmental Space Low Smoke Zero Halogen (LSZH) | Riser
Installation Temperature -30 °C to +60 °C (-22 °F to +140 °F)
Operating Temperature -40 °C to +70 °C (-40 °F to +158 °F)
Storage Temperature -40 °C to +75 °C (-40 °F to +167 °F)
Mechanical Test Specifications
Compression 126 lb/in | 22 N/mm
Compression Test Method FOTP-41 | IEC 60794-1 E3
Flex 100 cycles
Flex Test Method FOTP-104 | IEC 60794-1 E6
Impact 4.34 ft lb | 5.88 N-m
Impact Test Method FOTP-25 | IEC 60794-1 E4
Strain See long and short term tensile loads
Strain Test Method FOTP-33 | IEC 60794-1 E1
Twist 10 cycles
Twist Test Method FOTP-85 | IEC 60794-1 E7
Water Penentration 24 h
Water Penentration Test Method FOTP-82 | IEC 60794-1 F5
Environmental Test Specifications
Cable Freeze Test Method IEC 60794-1 F15
Heat Age -40 °C to +85 °C (-40 °F to +185 °F)
Heat Age Test Method IEC 60794-1 F9
Low High Bend -40 °C to +70 °C (-40 °F to +158 °F)
Low High Bend Test Method FOTP-37 | IEC 60794-1 E11
Temperature Cycle -40 °C to +70 °C (-40 °F to +158 °F)
Temperature Cycle Test Method FOTP-3 | IEC 60794-1 F1
Fale com nossos especialistas em SYSTIMAX
Veja mais
CABO OPTICO SM 9/125 EXTERNO AUTO-SUSTENTAVEL 6F
- Código GP Cabling: 18006
- Part Number: CFOA-SM-ASU80-06-NR
- Unidade: Metro
CORDÃO ÓPTICO DUPLEX 50,0/125 LC/LC OM2 1,5M
- Código GP Cabling: 44138
- Part Number: N222.2LLY1
- Unidade: Peça
CORDÃO ÓPTICO DUPLEX SM- OS2 LC/LC LSZH 3,0 M AMARELO
- Código GP Cabling: 95920
- Part Number: 2105028-3
- Unidade: Peça
CORDAO DUPLEX LAZRSPEED LC/LC 10FT - 3,05M
- Código GP Cabling: 50475
- Part Number: FDXLCLC42-MXF010
- Unidade: Peça